CFSQB - FLUX SOLV, 19-328-22

  • MSDS: CFSQB
  • Manufacturer: GC THORSEN
  • Product Name: FLUX SOLV, 19-328-22
  • National Stock Number: 3439-00N080792
Product Identification

Product ID:FLUX SOLV, 19-328-22
MSDS Date:04/03/1996
FSC:3439
NIIN:00N080792
MSDS Number: CFSQB

Responsible Party
GC THORSEN
1801 MORGAN ST
ROCKFORD, IL 61105-1209
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 815-968-9661

Preparer: M. WINSEL

Cage: EO177

Contractor
GC THORSEN
1209 ROCKFORD, IL 61105-1209 US

Telephone: 815-968-9661

Cage: EO177

Ingredients

ETHANE, 1,1-DICHLORO-1-FLUORO-; (DICHLOROFLOROETHANE (14

CAS: 1717-00-6

RTECS: KI0997000

Fraction By Weight: <72%

OSHA PEL N/K

ACGIH TLV: N/K


ISOPROPYL ALCOHOL (SARA 313)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 25%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM; 500 STEL


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 3%

OSHA PEL 5000 PPM

ACGIH TLV: 5000 PPM; 30000 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATERIALS
HAVE PRODUCED SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS
(IE, EPINEPHRINE) MAY BE CONTRA-I NDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CFCS . (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CONJUNCTIVITIS, DERMATITIS,
DIZZINESS, MENTAL CONFUSION, DROWSINESS, INCOORDINATION. (PERSONS
WITH CARDIOVASCULAR, LIVER OR KIDNEY PROBLEMS SHOULD AVOID
EXPOSURE.)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CONSULT MD.
SKIN: WASH WITH SOAP AND WATER. INHALATION: REMOVE TO FRESH AIR -
OXYGEN, ARTIFICIAL RESPIRATION - CONSULT MD (NO EPINEPHRINE).
INGESTION: I NDUCE VOMITING. CONSULT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:71.0F,21.7C
Lower Limits:2.2%
Upper Limits:14.0%
Extinguishing Media:CARBON DIOXIDE, WATER FOG, CHEMICAL FOAM.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA AND
FULL PROTECTIVE EQUIPMENT . TOXIC FUMES ARE EMITTED. COOL
CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE FLUORIDES, CHLORIDES AND PHOSGENE . TOXIC GASES EMITTED AT
EXTREME HIGH TEMPERATURES.

Accidental Release

Spill Release Procedures:DIKE SPILL. PICK UP WITH INERT ABSORBENT.
STORE IN STEEL CONTAINER FOR DISPOSAL. AVOID IGNITION SOURCES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID ALUMINUM CONTAINERS AND
INCOMPATIBLE MATERIALS. STORAGE AT TEMPERATURES ABOVE 120F - CANS
MAY BURST.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR
PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH APPROVED SCBA OR CARTRIDGE RESPIRATOR AS
NEEDED FOR EMERGENCIES.
Ventilation:LOCAL EXHAUST. MECHANICAL AS REQUIRED TO MEET TLVS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
CLOTHING AS NECESSARY TO AVOID REPEATED OR PROLONGED SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:85.0F,29.4C
Vapor Pres:9 PSIA
Vapor Density:3.9
Spec Gravity:1.1
VOC Pounds/Gallon:196
Evaporation Rate & Reference:>1 (ETHER =1)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID WITH ETHEREAL AND SWEETISH ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALUMINUM, N*2O*4, LIQUID OXYGEN, NA, NAOH, NAK.
Stability Condition to Avoid:IGNITION SOURCES, HIGH TEMPERATURES.
Hazardous Decomposition Products:PHOSGENE . CHLORINE, FLUORINE MAY BE
PRODUCED AT 1,100F PLUS.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . LICENSED INCINERATION OR SOLVENTS
RECLAIMER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.